RTP5000 Series

Power Sensor by Boonton (10 more products)

Note : Your request will be directed to Boonton.

RTP5000 Series Image

The RTP5000 Series of USB Power Sensors from Boonton are Real-Time peak power sensors that operate from 50 MHz to 40 GHz (available in 6 GHz, 18 GHz and 40 GHz configurations). They have a dynamic range from -60 dBm to +20 dBm with a measurement rate of 100,000 measurements per second, with no gaps in signal acquisition and zero measurement latency. These usb power sensors have a high video bandwidth and fast rise times.

These power sensors can be used in a wide range of applications including carrying out Crest Factor and Peak to Average Power Ratio (PAPR) measurements for Power Amplifiers and RF components. They can be used to test power levels of Wi-Fi, Telecommunication & Satellite signals. They can also be used to for RF and Microwave pulse modulated power measurements: RADAR, MRI, Particle Accelerators. Other General purpose scalar measurements such as gain and return loss using modulated, pulsed and CW signals can also be made.

Product Specifications

View similar products

Product Details

  • Part Number
    RTP5000 Series
  • Manufacturer
    Boonton
  • Description
    Real-Time Peak USB Power Sensors from 50 MHz to 40 GHz

General Parameters

  • Frequency
    50 MHz to 40 GHz
  • Applications
    Wi-Fi, Telecommunications, Satellite, Radar
  • Power Measurement
    Peak Power, Average Power / CW
  • Command Protocol
    IVI-C and IVI-Com
  • Power Range
    -50 to 20 dBm
  • Peak Power Range
    30 dBm
  • Continuous Sample Rate
    100 MS/s
  • Effective Sample Rate
    10 GHz
  • External Trigger in Out
    TTL in (slave) or out (master)
  • Connector
    N Type, 2.92 mm
  • Impedance
    50 Ohms
  • Interface
    USB, Type B Connector
  • Internal Trigger Range
    -38 to +20 dBm
  • Max Power Sensitivity
    20 dBm
  • Max Trigger Frequency
    50 MHz
  • Min Power Sensitivity
    -60 dBm
  • Min Trigger Width
    10 ns
  • Dynamic Range
    -60 to 20 dBm
  • Power Consumption
    2.5 W
  • Pulse Dynamic Range
    -50 to +20 dBm
  • Sample Rate
    10 GS/s
  • Sampling Techniques
    Real-time/Equivalent Time/ Statistical Sampling
  • Rise time
    100 ns to 10 µs
  • Single Shot Bandwidth
    6 to 35 MHz
  • Statistical Speed
    100M points/sec
  • Time Resolution
    100 ps
  • Trigger Jitter
    0.1 ns rms
  • Trigger Modes
    Auto, Normal, Single, Free run
  • Trigger Sources
    Internal or External TTL

Technical Documents

Embed Videos


Measuring Basic Pulse Parameters with a Boonton RTP5000 and Boonton Power Analyzer Software