SNA6000A

Vector Network Analyzer by SIGLENT (6 more products)

Note : Your request will be directed to SIGLENT.

SNA6000A Image

The SNA6000A Series from Siglent are 2/4-Port Vector Network Analyzers (VNA) that operate from 100 kHz to 13.5/26.5 GHz with a frequency resolution of 1 Hz. They have a dynamic range of 135 dB and a level resolution of 0.05 dB. These VNAs provide instantaneous measurement results of parameters such as Q-factor, bandwidth, and insertion loss, as well as insights into scattering, differential, and time-domain measurements. They support five different types of sweeps: linear-frequency, log-frequency, power-sweep, CW-time, and segment-sweep mode.

The SNA6000A Series VNAs offer various types of signal measurements that include impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, spectrum analysis frequency offset, and adapter removal/insertion adjustments. They also support multiple calibration methods such as response calibration, enhanced response calibration, full one-port calibration, full two-port calibration, full three-port calibration, full four-port calibration, and TRL calibration.

These 2/4-port VNAs have a 12.1-inch touch-screen display in addition to the front-panel controls. They consist of bias-tee connections for proper DC biasing and integrate LAN, USB device, and USB host (USB-GPIB) interfaces to allow remote control operation via SCPI, Labview, IVI based on USB-TMC, VXI-11, socket, Telnet, and WebServer commands. The SNA6000A Series VNAs also have an HDMI port to connect the VNA to equipment such as a projector for displaying results on a larger screen, adding flexibility to the device. They are available in benchtop enclosures that measure 426 x 251 x 494.5 mm.

Product Specifications

View similar products

Product Details

  • Part Number
    SNA6000A
  • Manufacturer
    SIGLENT
  • Description
    2/4-Port Vector Network Analyzers from 100 kHz to 13.5/26.5 GHz

General Parameters

  • Type
    USB / Computer Controlled, VNA with Screen
  • Equipment Type
    Benchtop
  • Ports
    2 Ports, 4 Ports
  • Port Connectors
    3.5 mm NMD - Male
  • Frequency
    100 kHz to 13.5 GHz / 100 kHz to 26.5 GHz
  • Frequency Resolution
    1 Hz
  • Test Points
    2 to 100, 001
  • Dynamic Range
    120 to 139 dB
  • Power Sweep Range
    -55 dBm to 10 dBm
  • Noise Floor
    -135 to -115 dBm/Hz
  • Directivity
    35 to 41 dB
  • Application
    Test & Measurement
  • IF Bandwidth
    1 Hz to 10 MHz
  • Harmonics
    -10 dBc
  • Temperature
    0 to 40 Degree C (Operating) & -20 to 60 Degree C (Storage)
  • Linearity
    ±0.5 dB
  • Interface
    LAN, USB Device, USB Host(USB-GPIB)
  • Display
    12.1 inch TFT color LCD with touch screen WXGA (1280 x 800)
  • Supply Voltage
    100 to 240 V
  • Dimensions
    W×H×D = 426×251×494.5 mm
  • Weight
    4-port or SNA6034A/SNA6134A: 19 kg
  • Note
    Phase Noise: -98dBc/Hz (1GHz@100kHz)