Anechoic Chambers - 3 m

29 Anechoic Chambers from 5 Manufacturers meet your specification.
Selected Filters Reset All
  • Test Distance : 3 m
Description:3-meter EMC Test Chamber
Type:
Fully Anechoic
Test Distance:
3 m
Frequency:
26 MHz to 40 GHz
Shielding Effectiveness:
100 dB
External Dimensions:
9.4 x 6 x 6 m
Internal Dimensions:
8.9 x 5.6 x 5.4 m
Emc Standards:
ANSI C63.4, CISPR 16-1-4, IEC 6100-4-3
more info
Description:Semi Anechoic 3m EMC Chamber with dome-shape design
Type:
Semi Anechoic
Test Distance:
3 m
Frequency:
9 kHz/ 26 MHz to 18 GHz
External Dimensions:
8.48 x 6.53 x 6 mm
Emc Standards:
CISPR 16-1-4, ANSI C63.4, IEC/EN 61000-4-3
more info
Description:3m Compliant Fully Anechoic EMC Test Chamber
Type:
Fully Anechoic
Test Distance:
3 m
Frequency:
80 MHz to 6 GHz
External Dimensions:
9 x 5 x 5 m
Emc Standards:
CISPR 16-1-4, IEC/EN61000-4-3, ANSI C63.4, CISPR 1...
more info
Description:3 m Anchoic Chamber from up to 110GHz
Test Distance:
3 m
Frequency:
up to 110GHz
External Dimensions:
7.0m (L) x 4.0m (W) x 4.0m (H)(Type A), 6.0m (L) x...
Internal Dimensions:
5.8m (L) x 3.0m (W) x 3.0m (H)(Type A), 5.1m (L) x...
more info
Description:3 m Semi Anchoic Chamber from 26 MHz and 18 GHz
Type:
Semi Anechoic
Test Distance:
3 m
Frequency:
26 MHz and 18 GHz
External Dimensions:
7.5 m long, 3.0 m wide and 4.0 m high (24'-7" x 13...
Emc Standards:
EN 50147-2, ANSI C63.4, CISPR 22, IEC 1000-4-3
more info
Description:3 m Semi Anchoic Chamber from 30 MHz to 18 GHz
Type:
Semi Anechoic
Test Distance:
3 m
Frequency:
30 MHz to 18 GHz
Shielding Effectiveness:
80 dB
Emc Standards:
CISPR 16-1-4, IEC/EN 61000-4-3, EN 50147-1, ANSI C...
more info
Description:10m Compliant Semi-Anechoic EMC Test Chamber
Type:
Semi Anechoic
Test Distance:
3 m, 5 m, 10 m
Frequency:
30 MHz to 18 GHz
External Dimensions:
22 x 16 x 10 m
Emc Standards:
CISPR 16-1-4, IEC/EN61000-4-3, ANSI C63.4, CISPR 1...
more info
Description:3 m Fully Anchoic Chamber from 30 MHz to 18 GHz
Type:
Fully Anechoic
Test Distance:
3 m
Frequency:
30 MHz to 18 GHz
Shielding Effectiveness:
80 dB
Emc Standards:
CISPR 16-1-4, IEC/EN 61000-4-3, EN 50147-1, ANSI C...
more info
Description:Semi Anechoic 10m EMC Chamber with Long-pyramid P2400 Absorbers
Type:
Semi Anechoic
Test Distance:
3 m, 5 m, 10 m
Frequency:
9 kHz/ 26 MHz to 18 GHz
External Dimensions:
23.48 x 16.58 x 9 mm
Emc Standards:
CISPR 16-1-4, ANSI C63.4, IEC/EN 61000-4-3
more info
Description:10m Compliant Semi-Anechoic EMC Test Chamber
Type:
Semi Anechoic
Test Distance:
3 m, 5 m, 10 m
Frequency:
30 MHz to 18 GHz
External Dimensions:
18 x 13 x 8.5 m
Emc Standards:
CISPR 16-1-4, IEC/EN61000-4-3, ANSI C63.4, CISPR 1...
more info

FiltersReset All

Type

Test Distance

Frequency (MHz)

Apply

Shielding Effectiveness (dB)

Apply