EMC Immunity Test Systems

7 EMC Immunity Test Systems from 3 Manufacturers meet your specification.
Selected Filters Reset All
  • Manufacturers: FRANKONIA, AMETEK CTS, Teseq
Description:Radiated Immunity Test System 6 GHz
Test Type:
Radiated Immunity
EMC Standards:
IEC/EN 61000-4-3, IEC/EN 61000-4-20, IEC/EN 61000-...
Configuration:
Stand Alone / Integrated System
Equipments:
Signal Generator
Signal Generator Frequency:
80 MHz to 6 GHz
Power Level Range:
-60 to 10 dBm
more info
Description:Radiated Immuniity EMC Test & Control Unit
Test Type:
Radiated Immunity
Frequency:
9 kHz to 3 GHz
Configuration:
Test Setup/Turn-key Test System
Equipments:
Power Amplifier, Signal Generator, Power Meter
Signal Generator Frequency:
9 kHz to 3 GHz
Power Level Range:
-65 dBm to +10 dBm
more info
Description:Single Phase AC/DC Voltage Source 2 kVA, galvanically isolated
Test Type:
Conducted Immunity, Radiated Immunity
Frequency:
10 Hz to 250 KHz
EMC Standards:
EMC-CS-2009.1, EMC-CS-2010JLR V1
Configuration:
Stand Alone / Integrated System
Equipments:
Power Amplifier, Signal Generator, Field Probe and...
Field Strength:
30 to 1000 A/m
Output Power:
100 W
more info
Description:Low frequency immunity test system
Test Type:
Radiated Immunity
Frequency:
DC to 150 kHz
EMC Standards:
IEC/EN 61000-4-16, IEC/EN 61000-4-19, IEC/EN 61000...
Configuration:
Stand Alone / Integrated System
Equipments:
Power Amplifier, Signal Generator
more info
Description:Radiated Immuniity EMC Test & Control Unit
Test Type:
Radiated Immunity
Frequency:
9 kHz to 6.5 GHz
Configuration:
Test Setup/Turn-key Test System
Equipments:
Power Amplifier, Signal Generator, Power Meter
Signal Generator Frequency:
9 kHz to 6.5 GHz
Power Level Range:
-100 dBm to +13 dBm
more info
Description:Test System for Conducted and Radiated Immunity
Test Type:
Radiated Immunity
EMC Standards:
IEC/EN 61000-4-3, IEC/EN 61000-4-6, IEC/EN 61000-4...
Configuration:
Stand Alone / Integrated System
Equipments:
Power Amplifier, Signal Generator, Power Meter
Amplifier Frequency:
9 kHz to 1 GHz
Output Power:
35 to 110 W
Signal Generator Frequency:
4 kHz to 1 GHz
Power Level Range:
-60 to 10 dBm
more info
Description:Simulator for conducted, common-mode disturbances, as per IEC 61000-4-16, IEC 61000-4-19 Annex C, 0Hz (DC) to 165kHz
Test Type:
Conducted Immunity
Frequency:
DC to 165 kHz
Configuration:
Stand Alone / Integrated System
Equipments:
Power Amplifier, Signal Generator
more info

FiltersReset All

Test Type

Frequency

 
 
Apply

Configuration

Equipments