Full Fan Out Handover Test Systems

22 Full Fan Out Handover Test Systems from 2 Manufacturers meet your specification.

Full Fan Out Handover Test Systems are devices that are used to simulate the process of handover of signals from one base station to the next in cellular or WLAN networks within the controlled space of laboratories. Full Fan Out Handover Test Systems from the leading manufacturers are listed below. Use the parametric search tools to narrow down on products by configuration, interface, attenuation, power and various other parameters. View product details, download datasheets and get quotes on matching products.

Selected Filters Reset All
  • Type: Full Fan Out
Description:4x4 Full Fan-Out Handover Test System from 1 to 8 GHz
Attenuation Accuracy:
±0.5 to ±1.25 dB
Configuration:
4x4
Control Interface:
Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100 to 240 Vac
Attenuation:
0 to 70 dB
Input Power:
30 dBm (IN ports) & 24 dBm (OUT ports)
Insertion Loss:
28 to 30 dB
more info
Description:12 x 12 Fan-Out Handover Test System from 0.8 to 3 GHz
Attenuation Accuracy:
+/- 0.50 dB, +/- 1.00 dB, +/- 1.25 dB
Configuration:
12x12
Control Interface:
Ethernet, RS-232, USB
Type:
Full Fan Out
AC Supply Voltage:
100 to 240 V
Attenuation:
0 to 127 dB
Input Power:
5 W
more info
Description:8x8 Full Fan-Out Handover Test System from 2 to 6 GHz
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8x8
Control Interface:
Ethernet, Manual, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
95 dB
Input Power:
1 W
Insertion Loss:
29 to 37 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 8x16 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8x16
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 to 36 dBm
Insertion Loss:
33 to 44 dB
more info
Description:30 to 3000 MHz, 0 to 95 dB 12x12 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
12x12
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
1 W
Insertion Loss:
44 to 47 dB
more info
Description:48x6 Full Fan-Out Handover Test System from 700 to 3000 MHz
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
48x6
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
1 W
Insertion Loss:
46 to 49 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 4x4 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
4x4
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
1 W
Insertion Loss:
29.4 to 31.3 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 4x2 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
4x2
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
26 to 30 dBm
Insertion Loss:
20 to 28 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 4x8 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
4x8
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 to 33 dBm
Insertion Loss:
34 to 36 dB
more info
Description:698 to 3000 MHz, 0 to 95 dB 8x8 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8x8
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 dBm
Insertion Loss:
29 to 34 dB
more info

What is a Full Fan-out Handover Test System?

These handover test systems are used to test multiple access points and mobile devices. Full fan-out systems are designed with power dividers/combiners on both halves of the matrix with a step attenuator on every path through the matrix. Every RF path through the matrix can have its own unique attenuation value and this allows the signal between each access point and mobile device to be individually faded up or down as required.

Full Fan Out Hand Over Test Systems from the leading manufacturers are listed on everything RF. Narrow down on the list of products by frequency, configuration and various other parameters. View product details, download datasheets and get quotes on products.

FiltersReset All

Configuration

Control Interface

Type

Attenuation (dB)

Apply

Input Power (W)

Apply