Magnetrons from Stellant Systems are listed on everything RF. We have compiled a list of Magnetrons from the Stellant Systems website/catalog and made their products searchable by specification. Use the filters to narrow down on products based on your requirements. Download datasheets and request quotes for products that you find interesting. Your inquiry will be directed to Stellant Systems and their distributors in your region.

Selected Filters Reset All
  • Manufacturers: Stellant Systems
Description:100 kW, Air and Water Cooled Magnetron from 896 to 929 MHz
Application:
Industrial, Military, Space, Medical
Frequency:
896, 911, 915, 922, 929 MHz
Band:
L Band
Anode Voltage:
18.8 to 21 kV
Avg Anode Current:
6200 to 6500 mA
Output Power:
100 kW
Cooling:
Air, Liquid
more info
Description:75 kW CW L- Band Magnetron from 896 to 929 MHz
Type:
Tunable Frequency, Fixed Frequency
Application:
Industrial, Medical
Frequency:
896, 911, 915, 922, 929 MHz
Band:
L Band
Anode Voltage:
18 to 19 kV
Peak Anode Current:
4.75 to 6 A
Output Power:
75 kW
Magnet:
Electromagnet
Cooling:
Air, Liquid-Cooled
more info
Description:70 kW, Coaxial Pulsed Magnetron from 9355 to 9395 MHz
Type:
Fixed Frequency
Application:
Airborne, Space, Industrial, Medical
Frequency:
9375 ± 20 MHz
Avg Anode Current:
15 A (Pulse)
Heater Current:
2.2 A
Heater voltage:
12.6 V
Output Power:
70 kW
Cooling:
Air
more info
Description:240 W, X Band Coaxial Pulsed Magnetron from 9275 to 9325 MHz
Type:
Tunable Frequency
Application:
Industrial, Medical
Frequency:
9.275 to 9.325 GHz
Band:
X Band
Anode Voltage:
34 to 38 kV (Peak)
Avg Anode Current:
12 mA
Peak Anode Current:
93 A
Output Power:
240 W
Magnet:
Integral permanent
Cooling:
Water-Cooled
more info
Description:1.6 kW, X Band Coaxial Pulsed Magnetron from 9275 to 9315 MHz
Type:
Tunable Frequency
Application:
Industrial, Medical
Frequency:
9.275 to 9.315 GHz
Band:
X Band
Anode Voltage:
34 to 38 kV (Peak)
Avg Anode Current:
74 mA
Peak Anode Current:
93 A
Output Power:
1600 W
Magnet:
Integral permanent
Cooling:
Water-Cooled
more info
Description:400 W, X Band Coaxial Pulsed Magnetron from 9275 to 9325 MHz
Type:
Tunable Frequency
Application:
Industrial, Medical
Frequency:
9.275 to 9.325 GHz
Band:
X Band
Anode Voltage:
34 to 38 kV (Peak)
Avg Anode Current:
19 mA
Peak Anode Current:
93 A
Output Power:
400 W
Magnet:
Integral permanent
Cooling:
Water-Cooled