RF Probes

23 RF Probes from 5 Manufacturers meet your specification.
Selected Filters Reset All
  • Configuration: GSG
  • Type: Coaxial Probe
Description:GSG Coaxial Probe from DC to 220 GHz
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 220 GHz
Pitch range:
50 µm, 75 µm and 100 µm
more info
Description:DC to 40 GHz Coaxial RF Probes with 0.8, 1.5, and 2.5 mm Pitch Range
Type:
Coaxial Probe
Configuration:
GS, GSG
Frequency:
DC 20 / 40 GHz
Insertion loss:
0.5 dB
Pitch range:
0.8 / 1.5 / 2.5 mm
Connector:
2.92 mm, 2.92 mm - Female, 3.5 mm, 3.5 mm - Female
more info
Description:High Performance RF/mmWave Probes up to 110 GHz
Type:
Coaxial Probe
Configuration:
GS, SG, GSG
Frequency:
DC to 110 GHz
Insertion loss:
0.8 to 2 dB
Pitch range:
45 to 250 µm
Connector:
1.85 mm, 1.85 mm - Female
more info
Description:DC to 40 GHz, Board Test and Signal Integrity Probes
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 40 GHz
Insertion loss:
1.0 dB
Pitch range:
100 to 250 µm
Connector:
2.92 mm, 2.92 mm - Female
more info
Description:DC to 20 GHz, GSG Coaxial Probe with 0.8 mm Pitch range
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 20 GHz
Insertion loss:
0.5 dB
Pitch range:
0.8 mm
Connector:
3.5 mm, 3.5 mm - Female
more info
Description:DC to 20 GHz, GSG Coaxial Probe with 1.5 mm, 2.5 mm Pitch range
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 20 GHz
Insertion loss:
0.5 dB
Pitch range:
1.5 mm, 2.5 mm
Connector:
3.5 mm, 3.5 mm - Female
more info
Description:RF Coaxial GSG Probe, 800 Micron Pitch, Up to 20 GHz, Cable Mount, 3.5mm Interface
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 20 GHz
Insertion loss:
0.5 dB
Pitch range:
800 µm(0.03 in)
Connector:
3.5 mm, 3.5 mm - Female
more info
Description:RF Coaxial GSG Probe, 1,500 Micron Pitch, Up to 20 GHz, Cable Mount, 3.5mm Interface
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 20 GHz
Insertion loss:
0.5 dB
Pitch range:
1500 µm(0.06 in)
Connector:
3.5 mm, 3.5 mm - Female
more info
Description:DC to 40 GHz, GSG Coaxial Probe with 1.5 mm, 2.5 mm Pitch range
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 40 GHz
Insertion loss:
0.5 dB
Pitch range:
1.5 mm, 2.5 mm
Connector:
2.92 mm, 2.92 mm - Female
more info
Description:DC to 40 GHz T-Probe with 0.8 mm Pitch range
Type:
Coaxial Probe
Configuration:
GSG
Frequency:
DC to 40 GHz
Insertion loss:
0.5 dB
Pitch range:
0.8 mm
Connector:
2.92 mm, 2.92 mm - Female
more info

FiltersReset All

Type

Configuration

Frequency

 
 
Apply

Insertion loss (dB)

Apply

Pitch range (µm)

Apply

Connector