RF Shielded Test Enclosures

570 RF Shielded Test Enclosures from 20 manufacturers listed on everything RF

A Shielded Test Enclosure is an enclosure that is used to test microwave devices in an environment isolated and free from interference due to other devices. RF Shielded Test Enclosures from the leading manufacturers are listed below. Use the filters to narrow down on products based on your requirement. Download datasheets and request quotes for products that you find interesting. Your inquiry will be directed to the manufacturer and their distributors in your region.

STE3000FAV2 Image
Description:Forensics RF Test Enclosure with Audio/ Video Recording
Configuration:
Portable
Opening Type:
Top
Chambers:
Single Chamber
Frequency:
upto 6 GHz
Isolation/Insulation:
80 to 90 dB
Interior Dimension:
23.3 x 17.2 x 23.6 Inches (W x H x D), 591.82 x 43...
Interior Width:
23.3 Inches
Interior Depth:
23.6 Inches
Interior Height:
17.2 Inches
Exterior Dimension:
19 x 25 x 25 Inches (H x W x D), 482 X 635 X 635 (...
Applications:
Wi-Fi, 802.11 a/b/g/n/ac, UMTS, Forensics
Package Type:
Benchtop
more info
Description:RF Shielded Test Enclosure Rack Mount from 20 MHz to 12 GHz
Configuration:
Fixed
Opening Type:
Front
Chambers:
Single Chamber
Frequency:
20 MHz to 12 GHz
Isolation/Insulation:
90 to 130 dB
Interior Dimension:
565 x 450 x 900 mm (W x H x D), 22.244 x 17.717 x ...
Interior Width:
22.244 Inches
Interior Depth:
35.433 Inches
Interior Height:
17.717 Inches
Exterior Dimension:
19.724 x 15.472 x 32.008 Inches (W x H x D), 501 x...
Applications:
Cellular, EMC/EMI, R&D, Bluetooth, RFID, 3G, 4G/LT...
Package Type:
Rackmount
more info
Description:300 MHz to 18 GHz Shielded Test Enclosure
Configuration:
Portable
Opening Type:
Top
Chambers:
Single Chamber
Frequency:
300 MHz to 18 GHz
Isolation/Insulation:
70 to 90 dB
Interior Dimension:
19 x 20 x 14.5 Inches (W x D x H), 482.6 x 508 x 3...
Interior Width:
19 Inches
Interior Depth:
20 Inches
Interior Height:
20 Inches
Exterior Dimension:
24 x 25 x 17 Inches (W x D x H), 609.6 x 635 x 431...
Applications:
Cellular, 4G/LTE, 5G, 802.11 a/b/g/n/ac/ax, Wi-Fi,...
Package Type:
Benchtop
more info
Description:RF Shielded Test Box from 0.3 to 6 GHz for Automatic Production Lines
Configuration:
Fixed
Opening Type:
Top
Chambers:
Single Chamber
Frequency:
0.3 to 6 GHz
Isolation/Insulation:
60 to 75 dB
Interior Dimension:
9.84 x 6.69 x 13.58 Inches, 250 x 170 x 345 mm
Exterior Dimension:
12.99 x 13.66 x 19.61 Inches, 330 x 347 x 498 mm
Applications:
4G/LTE, Wi-Fi, WiMax, Zigbee, Bluetooth, WLAN, ISM...
Package Type:
Stand Alone
more info
Description:Rugged RF and EMI Shielded Enclosure with Modular Panels
Configuration:
Fixed
Chambers:
Single Chamber
Frequency:
1 kHz to 40 GHz
Isolation/Insulation:
20 dB (Magnetic Field), 100 dB (Microwave), 110 dB...
Exterior Dimension:
34 x 36 x 36 Inches (W x H x L), 900 x 864 x 900 m...
Applications:
EMC/EMI
Package Type:
Stand Alone
more info
Description:RF Shielded Test Enclosure from 1 to 6 GHz
Configuration:
Portable
Opening Type:
Front
Chambers:
Dual Chamber
Frequency:
1 to 6 GHz
Isolation/Insulation:
80 to 90 dB
Interior Dimension:
8 x 17 x 8 Inches (H x W x D), 203.2 x 431.8 x 203...
Interior Width:
17 Inches
Interior Depth:
8 Inches
Interior Height:
8 Inches
Exterior Dimension:
17 x 12 x 13 Inches (W x H x D), 431 x 304 x 330 m...
Applications:
R&D, RFID, Test & Measurement, EMC/EMI, Bluetooth,...
Package Type:
Stand Alone
more info
Description:600 MHz to 43.5 GHz, Shielded Rf Test Enclosures
Configuration:
Portable
Opening Type:
Top
Chambers:
Single Chamber
Frequency:
600 MHz to 43.5 GHz
Isolation/Insulation:
50 dB
Exterior Dimension:
17.08 x 10.66 x 12.91 Inches (W x H x D ), 434 x 2...
Applications:
5G, 4G/LTE
Package Type:
Benchtop
more info
Description:90 dB, Front Opening RF Shielding Box from 100 MHz to 6 GHz
Opening Type:
Front
Chambers:
Single Chamber
Frequency:
100 MHz to 6 GHz
Isolation/Insulation:
90 dB
Interior Dimension:
18.9 x 11.02 x 11.02 Inches (L x D x H), 480 x 280...
Interior Width:
18.9 Inches
Interior Depth:
11.02 Inches
Interior Height:
11.02 Inches
Exterior Dimension:
19.68 x 11.81 x 11.81 Inches (W x H x L), 500 x 30...
Applications:
Wi-Fi, Bluetooth, RFID, 3G, WLAN, GPS/GNSS, WiMAX,...
more info
MBX-03 Image
Description:6x3x2 ft RF Shielded Test Enclosure from 18 to 95 GHz
Opening Type:
Front
Chambers:
Single Chamber
Frequency:
18 to 95 GHz
Interior Dimension:
1.57 x 7.87 x 4.33 Inches (T x H x W), 40 x 200 x ...
Interior Width:
4.33 Inches
Interior Height:
7.87 Inches
Exterior Dimension:
12 x 20 x 23 Inches (H x W x D), 300 x 500 x 580 m...
Applications:
Radar, 5G, 802.11 ad, 802.11 ay, Wi-Fi
more info
Description:Rack-Mountable RF Shield Box from 0.7 to 6 GHz
Configuration:
Portable
Opening Type:
Top
Chambers:
Single Chamber
Frequency:
700 MHz to 7 GHz
Isolation/Insulation:
60 dB
Applications:
Mobile Devices, Cellular, WLAN, Bluetooth, Zigbee,...
Package Type:
Benchtop
more info

What is a Shielded Test Enclosure or Box?

A shielded test box is an enclosure that is used test RF and Microwave devices in an isolated test environment, where there is no interference from other devices. These test boxes provide isolation from unintentional electromagnetic interference in noisy environments.

It is important to test devices in an isolated environment to understand how it performing. Shielded test enclosures provide an easy way to do this. Traditionally, this would need to be done in an anechoic chamber which is a large room and is comparatively very expensive. Shielded test chambers are compact boxes which can be placed on the table in a test lab.

Important Parameters of a Shielded Test Enclosure:

Type: This would be the configuration or form factor of the enclosure - Rack Mount Shielded Box, Stand Alone Shielded Box or Benchtop/Desktop Shielded Box.

Frequency Range: This is the frequency range in which the enclosure will provide isolation from interference. Based on the application of the device you need to test, you can pick a frequency that works best for you.

Isolation: This is the measure of the efficiency of the test enclosure i.e. higher the isolation, the better is the shielding the box provides.

Interface: This is important as is how you would connect to the devices places inside the shielded text box. These boxes usually support multiple interfaces with which you can connect to the device inside the box.

everything RF has listed shielded test boxes from the leading manufacturers in one place. You can use the filters provided to narrow down on test enclosures by frequency, isolation required or other parameters. Once you find a product that meets your spec. download the datasheet to learn more about it or Request a Quotation to get pricing on the box.

Filters

Manufacturers

Configuration

Opening Type

Chambers

Frequency

 
 
Apply

Isolation/Insulation (dB)

Apply

Interior Width

Apply

Interior Depth

Apply

Interior Height

Apply

Package Type