TEM / GTEM Cells

35 TEM / GTEM Cells from 6 manufacturers listed on everything RF

TEM / GTEM Cells from the leading manufacturers are listed below. Use the filters to narrow down on products based on your requirement. Download datasheets and request quotes for products that you find interesting. Your inquiry will be directed to the manufacturer and their distributors in your region.

Description:GTEM Cell for Emissions and Immunity Testing
Configuration:
Open
Door Size:
0.2 x 0.13 m
Frequency:
DC to 20 GHz
Septum Height:
250 mm
Shielding Effectiveness:
60 to 80 dB
Test Type:
Emission, Immunity
Type:
GTEM Cell
more info
Description:GTEM Cell For Emission & Immunity Testing, 0.01 MHz to 20 GHz
Door Size:
40 x 40 cm
Frequency:
0.01 MHz to 20 GHz
Septum Height:
500 mm
Test Type:
Emission, Immunity
Type:
GTEM Cell
Usable Test Area:
40 x 40 x 30 cm
more info
Description:Open TEM Cells For Emc Pre-compliance Testing
Configuration:
Open
Frequency:
Upto 1.15 GHz
Septum Height:
100 mm
Test Type:
Emission, Immunity
Type:
TEM Cell
Usable Test Area:
23 x 28 x 10 cm
more info
Description:Open TEM cell, DC - 1 GHz, plate height : 7.3 cm, 2.6 kV/m
Configuration:
Open
Frequency:
DC to 1 GHz
Septum Height:
73 mm
Test Type:
Immunity
Type:
TEM Cell
Usable Test Area:
220 x 210 mm
more info
Description:DC to 20 GHz, GTEM Cell For Emission & Immunity Testing
Configuration:
Open
Door Size:
747 x 686 mm
Frequency:
DC to 20 GHz
Septum Height:
897 mm
Shielding Effectiveness:
80 dB
Test Type:
Emission, Immunity
Type:
GTEM Cell
more info
Description:Pneumatic 6 GHz TEM Cell
Configuration:
Open, Closed
Frequency:
100 MHz to 6 GHz
Septum Height:
220 mm
Test Type:
Emission, Immunity
Type:
TEM Cell
more info
Description:GTEM Cell for Emissions and Immunity Testing, version for SAE
Configuration:
Open
Door Size:
0.2 x 0.13 m
Frequency:
DC to 20 GHz
Septum Height:
250 mm
Shielding Effectiveness:
90 to 100 dB
Test Type:
Emission, Immunity
Type:
GTEM Cell
more info
Description:GTEM Cell For Emission & Immunity Testing, 0.01 MHz to 20 GHz
Door Size:
60 x 60 cm
Frequency:
0.01 MHz to 20 GHz
Septum Height:
750 mm
Test Type:
Emission, Immunity
Type:
GTEM Cell
Usable Test Area:
60 x 60 x 50 cm
more info
Description:Open TEM Cells For Emc Pre-compliance Testing
Configuration:
Open
Frequency:
Upto 6 GHz
Septum Height:
28 mm
Test Type:
Emission, Immunity
Type:
TEM Cell
Usable Test Area:
19 x 7 x 2.8 cm
more info
Description:Open TEM cell, DC - 220 MHz, plate height: 33 cm, 800 V/m
Configuration:
Open
Frequency:
DC to 220 MHz
Septum Height:
364 mm
Test Type:
Immunity
Type:
TEM Cell
Usable Test Area:
860 x 900 mm
more info

Filters