DBR2-3.8

Low Noise Block by GeoSync Microwave (105 more products)

Note : Your request will be directed to GeoSync Microwave.

DBR2-3.8 Image

The DBR2-3.8 from GeoSync Microwave is a Low Noise Block with RF/Input Frequency 3.4 to 4.2 GHz, Output Frequency 950 MHz to 1.75 GHz, LO Frequency 8.55 / 11 GHz, Output Power 18 dBm, P1dB 18 dBm. More details for DBR2-3.8 can be seen below.

Product Specifications

View similar products

Product Details

  • Part Number
    DBR2-3.8
  • Manufacturer
    GeoSync Microwave
  • Description
    Single Band Block Downconverter from 3.4 to 4.2 GHz

General Parameters

  • Band
    Dual Band
  • RF/Input Frequency
    3.4 to 4.2 GHz
  • RF/Input Frequency Band
    S Band, C Band
  • Output Frequency
    950 MHz to 1.75 GHz
  • IF/Output Frequency Band
    L Band
  • LO Frequency
    8.55 / 11 GHz
  • Output Power
    18 dBm
  • P1dB
    18 dBm
  • IP3
    30 dBm
  • Gain
    35 dB, ±3 dB
  • Gain / Attenuation Control
    Yes
  • Gain Control Range
    30 dB
  • External Reference
    5/10 MHz
  • Gain Variation
    ±3 dB
  • Frequency Inversion
    Non Inversion
  • Humidity
    Up to 95% at 30 Degree C
  • Amplitude Response
    ±0.25 to ±1 dB
  • Intermodulation
    60 dBc
  • Number of LO
    Multiple
  • Image Rejection
    60 dB
  • Input Return Loss
    18 dB
  • Noise Figure
    15 dB
  • Power Consumption
    40 W
  • Output Return Loss
    18 dB
  • Return Loss
    18 dB
  • Spurious
    65 dBc
  • Spurious - Signal Dependent
    65 dBc
  • Spurious - Signal Independent
    -75 dBm
  • Phase Noise
    -90 to -60 dBc/Hz
  • Control
    Front Panel
  • AC Voltage
    90 to 250 Vac
  • Impedance
    50 Ohms
  • Dimension
    19 x 1.75 (panel height) x 20 Inches
  • Package
    Rack Mount
  • Connector
    SMA, SMA - Female, BNC, BNC - Female
  • RF Input Monitor
    SMA - Female
  • RF Input Connectors
    SMA - Female
  • External Reference Connector
    BNC - Female
  • IF Output Connector
    SMA - Female
  • Weight
    4.08 Kg(without rack slides), 5.9 Kg (with rack slides)
  • Altitude
    Operating : Up to 10, 000 feet, Non-operating : Up to 40, 000 feet
  • Operating Temperature
    0 to 50 Degree C